Items | Specifications |
Supply Voltage | 100/200 V AC (+10%, -15%), 50 to 60 Hz |
Supply Voltage Variation Range |
85 to 264 V AC |
Maximum Electric Power Consumption |
30 VA |
Maximum Inrush Current | 13 A, 1 ms (240 V AC) |
Storage Ambient Temperature |
-20˚C to 70˚C |
Use Ambient Temperature | 0˚C to 55˚C |
Use / Storage Ambient Humidity |
5% to 95% relative humidity (No condensation) |
Vibration Resistance | Compliant with JIS C60006-2-6 and sine wave oscillation test method MIL standards: 810C, Method: 514.2 |
Impact Resistance | Compliant with JIS C60006-2-27 MIL standards: 810C, Method: 516.2 |
Noise Resistance | NEMA (ICS3-304) |
Surrounding Atmosphere in Place of Use |
No corrosive gases |
Program Memory Capacity (Word) |
6 K |
Ladder Memory Capacity (Word) |
2,048 |
V Memory Capacity (Word) | 4,096 (Inner non-volatile user memory: 128) |
Battery Backup | Possible*1 |
Total Input/Output Points | 14 (Input: 8 Output: 6) |
Input/Output Expansion | Possible*1 |
Contact Point Execution (Boolean Operation) |
0.7 μs |
Standard Scan Time (During 1K Boolean Operation) |
1.5 to 3 ms |
Language System | Relay symbol type, stage type |
Rewrite During RUN | Possible |
Scan | Variable / Fixed |
Number of Instructions | 154 |
Internal Relay | 512 |
Timer | 128 |
Counter | 128 |
Instruction and Functions | Direct I/O, subroutine, For/Next loop, timer interruption, integer arithmetic, PID, drum sequence, word bit, ASCII print, real-time clock*1, calendar, internal diagnosis, password |
Filter Input | Possible |
Interrupt Input | Possible |
High Speed Counter | Possible, 5 kHz |
Pulse Catch Input | Possible |
Communication Function: Port 1 |
RS-232C Transmission speed: 9,600 bps (Fixed) Connection: 6-pin modular Protocol: K sequence (S), DirectNET (S), MODBUS (S) |
Communication Function: Port 2 |
RS-232C Transmission speed: 300, 600, 1,200, 2,400, 4,800, 9,600, 19,200, 38,400 bps Connection: 6-pin modular Protocol: K sequence (S), DirectNET (M/S), MODBUS (M/S), Non-procedure |